Compression load cell COL4-35


Download PDF

Compression load cells for weighing platforms, silos, hoppers etc..

Compression load cell

Upon request with ATEX or IECEx certification


Zoom Click to enlarge image

Compression load cell COL4-35 Compression load cell COL4-35 Schema
ATEX IECEX

Technical Specifications

MaterialStainless steel
Nominal load10, 30, 60, 100 t
Limit load150 % F.S.
Breaking load300 % F.S.
Supply voltageVcc 15 Max
Output2 mV/V
Output tollerance0,1 % F.S.
Zero tollerance1 % F.S.
Linearity0,1 % F.S.
Hysteresis0,1 % F.S.
Reapeatability0,1 % F.S.
Input resistance350-360 ohm
Output resistance350-353 ohm
Insulation resistance>= 2000 Mohm
Creep (30 Minutes)0,1 % F.S.
Thermal compensation-10 / +40°C (14 / +104°F)
Operating temperature-20 / +70°C (-4 / +158°F)
Temperature deviation zero0,003 % F.S. / °C
Temperature deviation full scale0,002 % F.S. / °C
Protection classIP 68
Standard cable lengthPanel male connector CR2R-07APNS (loose female connector CR2P-07ASNS-10), length to be defined
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

OptionalPanel male connector CR2R-07APNS
LengthCustom (body lead cell not connected shield)
Pin 1+ OUT
Pin 2- OUT
Pin 3NC
Pin 4NC
Pin 5NC
Pin 6+ IN
Pin 7- IN

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means